BRSRP - NICKEL-CADMIUM (NI-CD) BATTERY, VENTED

Product Identification

Product ID:NICKEL-CADMIUM (NI-CD) BATTERY, VENTED
MSDS Date:06/17/1993
FSC:6140
NIIN:00-134-0850
MSDS Number: BRSRP

Responsible Party
U.S. ARMY COMMUNICATIONS & ELECTRONICS MATERIAL
COMMAND LOGISTIC ENGINEERING DIRECTORATE
FT. MONMOUTH, NJ 07703
US

Emergency Phone: 800

Preparer: CECCM SAFETY OFFICE

Cage: KO177

Contractor
US ARMY COMMUNICATIONS & ELECTRONICS MATL READINES
FT. MONMOUTH, NJ 07703 US

Telephone: 732-532-5332

Cage: 80063

Ingredients

CADMIUM & CADMIUM HYDROXIDE

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: 7-26%

OSHA PEL SEE 1910.1027

ACGIH TLV: 0.01 MG/M3 DUST;9394

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


COBALT & COBALT HYDROXIDE

CAS: 7440-48-4

RTECS: GF8750000

Fraction By Weight: <2%

OSHA PEL 0.1 MG/M3;AS CO

ACGIH TLV: 0.05 MG/M3;DUST 9293


NICKEL & NICKEL HYDROXIDE

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 13-30%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9293


POTASSIUM HYDROXIDE 30% SOL.

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: <10%

OSHA PEL C, 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INTACT BATTERIES PRESENT NO SPECIFIC
HAZARDS. BURNING BATTERIES MAY EMIT TOXIC FUMES. LEAKING BATTERIES
LEAK CORROSIVE MATERIAL IRRITATING TO SKIN, EYES AND MUCOUS
MEMBRANES.
Explanation of Carcinogenicity:CADMIUM & NICKEL SUSPECT, NTP. CADMIUM &
COBALT COMPUNDS, IARC REGULATED.
Effects of Overexposure:ELECTROLYTE EXPOSURE TO SKIN/EYES WILL CAUSE
SEVERE IRRITATION. INHALATION OF FUMES MAY CAUSE SEVERE RESPIRATORY
IRRITATIUON.
Medical Cond Aggravated by Exposure:BURNING BATTERIES: RESPIRATORY
AILMENTS. LEAKING BATTERIES: SKIN CONDITIONS.

First Aid

First Aid:IF BATTERY CONTENTS COME IN CONTACT WITH THE BODY (E.G.,
HANDS, EYES, ETC.) WASH AFFECTED AREA FOR ATLEAST 15 MINUTES WITH
CLEAN WATER. DO NOT ATTEMPT TO NEUTRALIZE. SEEK MEDICAL ATTENTION
PROMPTLY.

Fire Fighting

Extinguishing Media:CARBON DIOXIDE OR DRY CHEMICAL FIRE EXTINGUISHER,
10-B:C.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE SELF-CONTAINED
BREATHING APPARATUS. BATTERY/CELLS MAY RELEASE TOXIC FUMES, IF
SUBJECTED TO FIRE/EXTREME.
Unusual Fire/Explosion Hazard:STRONG OXIDIZERS (E.G. ACIDS) & FIRE.

Accidental Release

Spill Release Procedures:AVOID SKIN OR EYE CONTACT. USE NONFLAMMABLE
ABSORBENT MATERIAL FOR CLEANUP. COORDINATE WITH INSTALLATION SAFETY
AND ENVIRONMENTAL OFFICES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT ABUSE OR SHORT CIRCUIT. WHEN
STORING BATTERIES, STORE IN A COOL, DRY & WELL VENTILATED AREA,
SEPERATE FROM OTHER HAZARDOUS MATERIAL.
Other Precautions:DO NOT INVERT OR CAUSE TO SPILL. RECHARGE IAW METHODS
SPECIFIED IN APPLICABLE TECHANICAL MANUAL.

Exposure Controls

Respiratory Protection:IF BATTERIES ARE BURNING USE SCBA.
Ventilation:LOCAL EXHAUST:WHEN SERVICING USE OSHA. MECHANICAL
(GENERAL):APPROVED FACILITY. SPECIAL:SELF-CONTAINED BREATHING
APPARATS
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:CHEMICALS SPLASH GOGGLES.
Other Protective Equipment:CHEMICALLY RESISTANT APRON.
Work Hygienic Practices:AVOIS SKIN OR EYE CONTACT WITH ELECTROLYTE. DO
NOT EAT OR SMOKE IN BATTERY SERVICE AREA.
Supplemental Safety and Health
PROPER SHIPPING NAME: BATTERY, WET FILLED WITH ALKALI, ELECTRIC
STORAGE.

Chemical Properties

HCC:B1

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS (E.G., ACIDS). STORE SEPERATELY FROM OTHER
HAZARDOUS MATERIALS, & GAIN FD APPROVAL FOR STORAGE.
Stability Condition to Avoid:FIRE AND EXTREME HEAT. DO NOT SHORT
CIRCUIT OR OVERCAHRGE.
Hazardous Decomposition Products:WHEN EXPOSED TO FIRE OR EXTREME HEAT,
BATTERIES MAY EMIT TOXIC FUMES.

Disposal

Waste Disposal Methods:NI-CD BATTERIES ARE CLASSIFIED AS HAZARDOUS
WASTE UNDER RCRA REGULATIONS, AND DISPOSITION ID THRU THE DRMO.
COORDINATE DISPOSITION WITH INSTALLATION ENVIRONMENTAL COORDINATOR.
RECYCLING IS THE PREFERR ED DISPOSITION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.